Key points
- SNI 1727:2020 adopts ASCE 7-16 and adds a ground elevation factor (Ke).
- Wind pressure increases with height, so wind loads are calculated floor by floor.
- Wind is checked for the main structure (MWFRS) and for components and cladding such as facades.
- Flexible tall buildings need checks for dynamic effects, drift and occupant comfort.

Wind loads on tall buildings get less attention in Indonesia than earthquake loads. Yet the taller and more slender a building is, the more wind affects its strength, its drift and the comfort of the people inside. This article explains what engineers consider when they calculate wind loads, in terms that owners and developers can follow.
The wind load standard in Indonesia
Minimum design loads for buildings in Indonesia are set by SNI 1727, currently the 2020 edition. A 2025 study in the ITB civil engineering journal notes that this Indonesian wind loading standard adopts the American standard ASCE 7-16.
Compared with the 2013 edition, a study from Universitas Sumatera Utara highlights two easy-to-grasp changes:
- The velocity pressure formula gains a ground elevation factor (Ke).
- Enclosure classification moves from three classes (enclosed, partially enclosed, open) to four (enclosed, partially enclosed, partially open, open).
So wind calculations made under the older edition should be reviewed when a building is re-assessed or redeveloped.
What drives wind loads on tall buildings
Put simply, wind pressure on a building comes from the wind speed multiplied by a set of correction factors. In SNI 1727:2020 the velocity pressure is written as qz = 0.613 Kz Kzt Kd Ke V². The factors mean:
| Factor | Meaning |
|---|---|
| V | Basic wind speed at the site, linked to the risk category |
| Kz | Effect of height and surface roughness (exposure) |
| Kzt | Effect of topography such as hills or escarpments |
| Kd | Wind directionality factor |
| Ke | Ground elevation factor |
The basic wind speed is defined at 10 metres above open, flat terrain. The exposure category describes the surroundings, from a dense city centre to an open coastline. A building in a crowded city receives more sheltered wind than the same building on the seafront.
The velocity pressure is then multiplied by a gust effect factor and pressure coefficients that depend on the building's shape, including internal pressure, which depends on the enclosure class.
Higher up, higher pressure
Wind speed increases with height, so upper floors receive more pressure than lower ones. That is why engineers calculate wind loads floor by floor rather than as one value for the whole building. Turbulence intensity, on the other hand, decreases with height.
The wind forces on each floor add up to a base shear and an overturning moment at the base, which are carried down to the foundations. In a slender building, this overturning moment can govern the pile design. Foundations for tall buildings are discussed in bored piles vs driven piles.
Two targets: the main structure and the envelope
Wind loads are calculated for two separate groups:
- The main wind force resisting system (MWFRS). The frames, shear walls and cores that keep the whole building from drifting too far or overturning.
- Components and cladding. Glass facades, curtain walls, panels and roofs. These receive local pressure and suction that can be much higher at corners and edges.
Tip: When planning a glass facade on a tall building, make sure the facade supplier uses design wind pressures agreed with the structural engineer, not a generic catalogue value.
Flexible buildings and dynamic effects
Tall, slender buildings have a low natural frequency. The ITB study explains that such flexible buildings experience larger wind effects because of resonance. Besides along-wind forces, tall buildings can also experience across-wind forces and torsion caused by vortices shedding from their sides.
The consequences go beyond strength:
- Inter-storey drift, which affects partitions, facades and lifts.
- Occupant comfort, because sway can be felt on upper floors. Comfort is usually judged by acceleration at the top occupied floors, against criteria set by the engineer for the building's use.
For unusual building shapes, pressure coefficients come from wind tunnel testing, which models the building and its surroundings at small scale.
Does wind or earthquake govern?
Indonesia is known for earthquakes, so many people assume earthquakes always govern. That is not always true. The ITB study states that tall buildings are more sensitive to wind than to earthquake loads, and for the supertall building it analysed in Jakarta, ASCE gave the highest wind load and structural response of the standards compared. The same study notes that the minimum design pressure in ASCE 7, as adopted in SNI, is quite conservative for Indonesian wind speeds.
In practice, engineers check both. Earthquake and wind are analysed separately, and each member is designed for the governing load combination. The lateral systems themselves, such as shear walls and moment frames, are covered in shear walls vs moment frames.
Tall residential projects with structures designed by Stadin include BSD Skyhouse, with 13 towers of 30 storeys, Alam Sutera Skyhouse, with 5 towers of 31–43 storeys, and Equator Apartment in Surabaya, at 37 storeys. At these heights, both wind and earthquake loads are part of the lateral system design.
Conclusion
Wind loads on tall buildings depend on the site's wind speed, height, surroundings, topography, the building's shape and its flexibility. SNI 1727:2020 brings changes from the 2013 edition, and flexible buildings need special attention to dynamic effects and occupant comfort. Every building must be calculated by a competent engineer, because the results depend heavily on the project. For your tall building project, talk to Stadin about structural design.
This article provides general information. Every project still needs to be analysed and calculated by a competent structural or geotechnical engineer, in line with the applicable SNI codes and regulations.
Sources
- Studi Komparasi Standar Desain Pembebanan Angin Untuk Bangunan Tinggi (Jurnal Teknik Sipil ITB, 2025)
- Analisis Perbandingan Standar Beban Angin pada Struktur Rangka Ruang (Academia Open, 2025)
- Analisis Struktur Gedung Tower I Apartement 25 Tingkat di Jakarta sebagai Sistem Penahan Beban Angin Utama (SPBAU), Universitas Mercu Buana
- Data proyek: company profile PT. Stadin Strukturindo Konsultan (2026)